1-Chloro-4-iodobutane
SpectraBase Compound ID IHIPux4TDnP
InChI InChI=1S/C4H8ClI/c5-3-1-2-4-6/h1-4H2
InChIKey JXOSPTBRSOYXGC-UHFFFAOYSA-N
Mol Weight 218.47 g/mol
Molecular Formula C4H8ClI
Exact Mass 217.935923 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 5qOpo2OUFB1
Name 1-Chloro-4-iodobutane
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number C2713
Lot Number PA5KA-SC
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270603
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 16
Background Scans or Time Scans
Backward Peak Amplitude -7443
Backward Peak Location 14480
Beam Splitter Setting KBr
CAS Registry Number 10297-05-9
Color Properties Colorless-yellow
Comments stabilized with copper chip
Container ID C-010453
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C4H8ClI
Frequency of First Point 3999.76 cm⁻¹
Frequency of Last Point 339.943 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C4H8ClI/c5-3-1-2-4-6/h1-4H2
InChIKey JXOSPTBRSOYXGC-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 218.465 g/mol
Non Linearity Correction 0
Number of Points 15181
Number of Sample Scans 16
Optical Filter Setting Open
Peak Amplitude -7344
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Liquid
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 10 %
Resolution 2
SKU C2713-5G
SMILES C(CI)CCCl
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 24.992 s
Scanner Temperature 30 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 4-Chlorobutyl iodide; 4-Iodobutyl chloride
Technique Neat
Window KBr Window - 1 Side
Zero Filling Factor 8