SpectraBase Spectrum ID |
5pGBrtVkyXM |
Name |
2-Bromo-2'-nitroacetophenone |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H30275 |
Lot Number |
10167157 |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270439 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-9853 |
Backward Peak Location |
14449 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
6851-99-6 |
Color Properties |
White |
Container ID |
C-008371 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C8H6BrNO3 |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C8H6BrNO3/c9-5-8(11)6-3-1-2-4-7(6)10(12)13/h1-4H,5H2 |
InChIKey |
SGXUUCSRVVSMGK-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
244.044 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-9549 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14507 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Solid |
Preamplifier Gain Background |
0 |
Purity |
98% |
Relative Humidity Interferometer |
20 % |
Resolution |
2 |
SKU |
H30275-1G |
SMILES |
N(=O)(=O)c1ccccc1C(CBr)=O |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.041 s |
Scanner Temperature |
28.4 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Solvent |
Dichloromethane |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
2-Nitrophenacyl bromide |
Technique |
Film |
Window |
KBr Window |
Zero Filling Factor |
8 |