SpectraBase Spectrum ID |
5jEpyLTboGH |
Name |
5,5-Dimethoxy-1,2,3,4-tetrachlorocyclopentadiene |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
T0928 |
Lot Number |
4FFCM-QP |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270585 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
16 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-8601 |
Backward Peak Location |
14480 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
2207-27-4 |
Container ID |
C-010467 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C7H6Cl4O2 |
Frequency of First Point |
3999.76 cm⁻¹ |
Frequency of Last Point |
339.943 cm⁻¹ |
High Folding Limit |
15800.4 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C7H6Cl4O2/c1-12-7(13-2)5(10)3(8)4(9)6(7)11/h1-2H3 |
InChIKey |
UHSMEJQTFMHABA-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
263.935 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15181 |
Number of Sample Scans |
16 |
Optical Filter Setting |
Open |
Peak Amplitude |
-8357 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14476 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Liquid |
Preamplifier Gain Background |
0 |
Purity |
>95.0% |
Relative Humidity Interferometer |
10 % |
Resolution |
2 |
SKU |
T0928-5G |
SMILES |
C1(\C(=C/(\C(=C/1Cl)Cl)Cl)Cl)(OC)OC |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
24.991 s |
Scanner Temperature |
30.1 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
1,2,3,4-Tetrachloro-5,5-dimethoxycyclopentadiene |
Technique |
Neat |
Window |
KBr Window - 1 Side |
Zero Filling Factor |
8 |