For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-Isopropyl-N,2,3-trimethylbutyramide
SpectraBase Compound ID 87kA7l9esre
InChI InChI=1S/C10H21NO/c1-7(2)10(5,8(3)4)9(12)11-6/h7-8H,1-6H3,(H,11,12)
InChIKey RWAXQWRDVUOOGG-UHFFFAOYSA-N
Mol Weight 171.28 g/mol
Molecular Formula C10H21NO
Exact Mass 171.162314 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 5gFvSCQjvV1
Name 2-Isopropyl-N,2,3-trimethylbutyramide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number I0729
Lot Number LTNPJ-CR
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270583
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -6911
Backward Peak Location 14480
Beam Splitter Setting KBr
CAS Registry Number 51115-67-4
Container ID C-010356
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C10H21NO
Frequency of First Point 3999.76 cm⁻¹
Frequency of Last Point 339.943 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C10H21NO/c1-7(2)10(5,8(3)4)9(12)11-6/h7-8H,1-6H3,(H,11,12)
InChIKey RWAXQWRDVUOOGG-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 171.284 g/mol
Non Linearity Correction 0
Number of Points 15181
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -6627
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 0 %
Resolution 2
SKU I0729-5G
SMILES N(C(C(C(C)C)(C(C)C)C)=O)C
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.048 s
Scanner Temperature 29.9 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Solvent Dichloromethane
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms Trimethyl isopropyl butanamide
Technique Film
Window KBr Window
Zero Filling Factor 8