5-Amino-1,3-diphenylpyrazole
SpectraBase Compound ID 5L9ZcOeGII7
InChI InChI=1S/C15H13N3/c16-15-11-14(12-7-3-1-4-8-12)17-18(15)13-9-5-2-6-10-13/h1-11H,16H2
InChIKey SXOFMEWDEKEVJU-UHFFFAOYSA-N
Mol Weight 235.29 g/mol
Molecular Formula C15H13N3
Exact Mass 235.110947 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 5YAVI57WKWu
Name 5-Amino-1,3-diphenylpyrazole
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A2904
Lot Number J6OMD-KK
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 4129
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 5356-71-8
Calibration Lamp Spectrum Correction.0
Color Properties White- reddish yellow
Container ID C-009475
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C15H13N3
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C15H13N3/c16-15-11-14(12-7-3-1-4-8-12)17-18(15)13-9-5-2-6-10-13/h1-11H,16H2
InChIKey SXOFMEWDEKEVJU-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 235.290 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 238
Optical Filter Setting Open
Peak Amplitude 4110
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU A2904-1G
SMILES Nc1[n](nc(c1)-c1ccccc1)-c1ccccc1
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 2,5-Diphenylpyrazol-3-amine
Technique FT-Raman
Zero Filling Factor 4