For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Malotilate
SpectraBase Compound ID 6wTzgBpMDrd
InChI InChI=1S/C12H16O4S2/c1-7(2)15-10(13)9(11(14)16-8(3)4)12-17-5-6-18-12/h5-8H,1-4H3
InChIKey YPIQVCUJEKAZCP-UHFFFAOYSA-N
Mol Weight 288.38 g/mol
Molecular Formula C12H16O4S2
Exact Mass 288.049001 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 5QoJFBouIFP
Name Malotilate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2674
Lot Number 3PIPD-TD
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2851
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 59937-28-9
Calibration Lamp Spectrum Correction.0
Color Properties Pale yellow
Container ID C-009441
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C12H16O4S2
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C12H16O4S2/c1-7(2)15-10(13)9(11(14)16-8(3)4)12-17-5-6-18-12/h5-8H,1-4H3
InChIKey YPIQVCUJEKAZCP-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 208
Optical Filter Setting Open
Peak Amplitude 2871
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU M2674-1G
SMILES S1\C=C/SC1=C(C(OC(C)C)=O)C(OC(C)C)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms Diisopropyl (1,3-dithiol-2-ylidene)malonate; (1,3-Dithiol-2-ylidene)malonic acid diisopropyl ester
Technique FT-Raman
Zero Filling Factor 4