For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3-Chloro-4-methoxybenzylamine hydrochloride
SpectraBase Compound ID GNDVxE947En
InChI InChI=1S/C8H10ClNO.ClH/c1-11-8-3-2-6(5-10)4-7(8)9;/h2-4H,5,10H2,1H3;1H
InChIKey IKWWOZCEHOYKAO-UHFFFAOYSA-N
Mol Weight 208.09 g/mol
Molecular Formula C8H11Cl2NO
Exact Mass 207.021769 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 5MiBAjnxeTb
Name 3-Chloro-4-methoxybenzylamine hydrochloride
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number C2903
Lot Number 3F2WI-I0
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270334
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1862
Backward Peak Location 7372
Beam Splitter Setting KBr
CAS Registry Number 41965-95-1
Color Properties White-pale yellow
Container ID C-009419
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C8H11Cl2NO
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C8H10ClNO.ClH/c1-11-8-3-2-6(5-10)4-7(8)9;/h2-4H,5,10H2,1H3;1H
InChIKey IKWWOZCEHOYKAO-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 208.088 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1878
Peak Amplitude 2nd Channel 1
Peak Location 7364
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 20 %
Resolution 4
SKU C2903-1G
SMILES Cl.NCc1cc(c(cc1)OC)Cl
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.31 s
Scanner Temperature 27.5 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 4-Aminomethyl-2-chloroanisole HCl
Technique ATR-Neat
Zero Filling Factor 4