SpectraBase Spectrum ID |
5IiWwi2UdCd |
Name |
2,4-Dichlorobenzophenone |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
D0342 |
Lot Number |
FIN01-SE0I |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
1 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.222558 |
Analog Signal 2 |
0 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Backward Peak Amplitude |
3203 |
Backward Peak Location |
28681 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
19811-05-3 |
Calibration Lamp Spectrum |
Correction.0 |
Color Properties |
White |
Container ID |
C-010246 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C13H8Cl2O |
Frequency of First Point |
3597.77 cm⁻¹ |
Frequency of Last Point |
-0.855506 cm⁻¹ |
High Folding Limit |
31596.9 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C13H8Cl2O/c14-10-6-7-11(12(15)8-10)13(16)9-4-2-1-3-5-9/h1-8H |
InChIKey |
VLTYTTRXESKBKI-UHFFFAOYSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Molecular Weight |
251.112 g/mol |
Non Linearity Correction |
0 |
Number of Points |
7465 |
Number of Sample Scans |
250 |
Optical Filter Setting |
Open |
Peak Amplitude |
-3217 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
28699 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Solid |
Preamplifier Gain |
0 |
Purity |
>97.0% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Relative Humidity Interferometer |
30 % |
Resolution |
2 |
SKU |
D0342-5G |
SMILES |
c1ccccc1C(c1ccc(cc1Cl)Cl)=O |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
794.612 s |
Scanner Temperature |
24.8 °C |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Technique |
FT-Raman |
Temperature of Calibration Lamp |
2300 |
Zero Filling Factor |
4 |