For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-Chloroethyl chloromethyl ether
SpectraBase Compound ID IN4DmYrTPHJ
InChI InChI=1S/C3H6Cl2O/c4-1-2-6-3-5/h1-3H2
InChIKey LUTWEKBTDWRTSE-UHFFFAOYSA-N
Mol Weight 128.99 g/mol
Molecular Formula C3H6Cl2O
Exact Mass 127.97957 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 5GdrZTOhoSp
Name 2-Chloroethyl chloromethyl ether
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number C1405
Lot Number UW5VF-DQ
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270562
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -8693
Backward Peak Location 14458
Beam Splitter Setting KBr
CAS Registry Number 1462-33-5
Color Properties Colorless-pale yellow
Container ID C-010187
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C3H6Cl2O
Frequency of First Point 3999.74 cm⁻¹
Frequency of Last Point 339.942 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C3H6Cl2O/c4-1-2-6-3-5/h1-3H2
InChIKey LUTWEKBTDWRTSE-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Non Linearity Correction 0
Number of Points 15181
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -8142
Peak Amplitude 2nd Channel 1
Peak Location 14498
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Liquid
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 10 %
Resolution 2
SKU C1405-5G
SMILES C(CCl)OCCl
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.105 s
Scanner Temperature 29.1 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 2-(Chloromethoxy)ethyl chloride
Technique Neat
Window KBr Window - 1 Side
Zero Filling Factor 8