For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3-(Trimethylsilylethynyl)thiophene
SpectraBase Compound ID 4VhNd3vV9Uf
InChI InChI=1S/C9H12SSi/c1-11(2,3)7-5-9-4-6-10-8-9/h4,6,8H,1-3H3
InChIKey XJUQFUWWPCIZRB-UHFFFAOYSA-N
Mol Weight 180.34 g/mol
Molecular Formula C9H12SSi
Exact Mass 180.042898 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 57JIp3Eyxpg
Name 3-(Trimethylsilylethynyl)thiophene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number T3190
Lot Number 2UDIO-BH
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270274
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 16
Background Scans or Time Scans
Backward Peak Amplitude -12416
Backward Peak Location 14479
Beam Splitter Setting KBr
CAS Registry Number 130995-13-0
Color Properties Pale yellow
Container ID C-009739
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C9H12SSi
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C9H12SSi/c1-11(2,3)7-5-9-4-6-10-8-9/h4,6,8H,1-3H3
InChIKey XJUQFUWWPCIZRB-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 16
Optical Filter Setting Open
Peak Amplitude -12280
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 2
SKU T3190-1G
SMILES c1scc(c1)C#C[Si](C)(C)C
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 24.992 s
Scanner Temperature 26.3 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Neat
Window KBr Window - 1 Side
Zero Filling Factor 8