2-Phenylethylamine hydrobromide
SpectraBase Compound ID J7932YfPxMK
InChI InChI=1S/C8H11N.BrH/c9-7-6-8-4-2-1-3-5-8;/h1-5H,6-7,9H2;1H
InChIKey IRAGENYJMTVCCV-UHFFFAOYSA-N
Mol Weight 202.09 g/mol
Molecular Formula C8H12BrN
Exact Mass 201.015312 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 4xxsAZwGB0T
Name 2-Phenylethylamine hydrobromide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number P2388
Lot Number 4DWPB-LO
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1476
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 53916-94-2
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009698
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H12BrN
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H11N.BrH/c9-7-6-8-4-2-1-3-5-8;/h1-5H,6-7,9H2;1H
InChIKey IRAGENYJMTVCCV-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 202.095 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 188
Optical Filter Setting Open
Peak Amplitude 1456
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU P2388-1G
SMILES Br.NCCc1ccccc1
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4