For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
4-n-Octylbiphenyl
SpectraBase Compound ID APbOhiSdasL
InChI InChI=1S/C20H26/c1-2-3-4-5-6-8-11-18-14-16-20(17-15-18)19-12-9-7-10-13-19/h7,9-10,12-17H,2-6,8,11H2,1H3
InChIKey KCLBLDDJJJNGBC-UHFFFAOYSA-N
Mol Weight 266.43 g/mol
Molecular Formula C20H26
Exact Mass 266.203451 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 4iPG15NQW47
Name 4-n-Octylbiphenyl
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number B25010
Lot Number J9120A
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270445
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1847
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 7116-97-4
Container ID C-009973
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C20H26
Frequency of First Point 3998.29 cm⁻¹
Frequency of Last Point 339.46 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C20H26/c1-2-3-4-5-6-8-11-18-14-16-20(17-15-18)19-12-9-7-10-13-19/h7,9-10,12-17H,2-6,8,11H2,1H3
InChIKey KCLBLDDJJJNGBC-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 266.428 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1876
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 20 %
Resolution 4
SKU B25010-1G
SMILES c1ccccc1-c1ccc(cc1)CCCCCCCC
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.293 s
Scanner Temperature 28.5 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4