For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
α-Asarone
SpectraBase Compound ID 6xK1hGhPK6I
InChI InChI=1S/C12H16O3/c1-5-6-9-7-11(14-3)12(15-4)8-10(9)13-2/h5-8H,1-4H3/b6-5+
InChIKey RKFAZBXYICVSKP-AATRIKPKSA-N
Mol Weight 208.26 g/mol
Molecular Formula C12H16O3
Exact Mass 208.109944 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 4hJnE7EXLYO
Name α-Asarone
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A2590
Lot Number N753J-AC
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 3079
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 2883-98-9
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-008189
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C12H16O3
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C12H16O3/c1-5-6-9-7-11(14-3)12(15-4)8-10(9)13-2/h5-8H,1-4H3/b6-5+
InChIKey RKFAZBXYICVSKP-AATRIKPKSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 208.257 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 246
Optical Filter Setting Open
Peak Amplitude 3021
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU A2590-1G
SMILES c1c(c(cc(c1\C=C\C)OC)OC)OC
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms trans-1,2,4-Trimethoxy-5-(1-propenyl)benzene; trans-1-Propenyl-2,4,5-trimethoxybenzene
Technique FT-Raman
Zero Filling Factor 4