For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
5-Amino-2-methylbenzonitrile
SpectraBase Compound ID FRGLvO4M3S1
InChI InChI=1S/C8H8N2/c1-6-2-3-8(10)4-7(6)5-9/h2-4H,10H2,1H3
InChIKey YDZVQWCVKXYGIU-UHFFFAOYSA-N
Mol Weight 132.17 g/mol
Molecular Formula C8H8N2
Exact Mass 132.068748 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 4h1wEWekNDN
Name 5-Amino-2-methylbenzonitrile
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A2814
Lot Number O4MWI-JK
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1965
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 50670-64-9
Calibration Lamp Spectrum Correction.0
Color Properties White-pale reddish yellow
Container ID C-009445
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H8N2
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H8N2/c1-6-2-3-8(10)4-7(6)5-9/h2-4H,10H2,1H3
InChIKey YDZVQWCVKXYGIU-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 132.166 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 196
Optical Filter Setting Open
Peak Amplitude 1897
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU A2814-1G
SMILES Nc1cc(c(cc1)C)C#N
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 5-Amino-o-tolunitrile
Technique FT-Raman
Zero Filling Factor 4