4-(trans-4-Vinylcyclohexyl)benzonitrile
SpectraBase Compound ID DA7jkKUrDkZ
InChI InChI=1S/C15H17N/c1-2-12-3-7-14(8-4-12)15-9-5-13(11-16)6-10-15/h2,5-6,9-10,12,14H,1,3-4,7-8H2/t12-,14-
InChIKey JHXJAWXZLWDDED-MQMHXKEQSA-N
Mol Weight 211.31 g/mol
Molecular Formula C15H17N
Exact Mass 211.1361 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 4UqjWj4gsfs
Name 4-(trans-4-Vinylcyclohexyl)benzonitrile
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number V0135
Lot Number CA8RC-DB
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1446
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 96184-42-8
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009561
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C15H17N
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C15H17N/c1-2-12-3-7-14(8-4-12)15-9-5-13(11-16)6-10-15/h2,5-6,9-10,12,14H,1,3-4,7-8H2/t12-,14-
InChIKey JHXJAWXZLWDDED-MQMHXKEQSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 150
Optical Filter Setting Open
Peak Amplitude 1424
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU V0135-1G
SMILES c1c(ccc(c1)[C@]1(CC[C@@](CC1)(C=C)[H])[H])C#N
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4