Meclofenoxate hydrochloride
SpectraBase Compound ID BRldk38Jl1I
InChI InChI=1S/C12H16ClNO3.ClH/c1-14(2)7-8-16-12(15)9-17-11-5-3-10(13)4-6-11;/h3-6H,7-9H2,1-2H3;1H
InChIKey FIVHOHCAXWQPGC-UHFFFAOYSA-N
Mol Weight 294.18 g/mol
Molecular Formula C12H17Cl2NO3
Exact Mass 293.058549 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 4RSB5wm6LN2
Name Meclofenoxate hydrochloride
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2460
Lot Number URIWC-AT
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1726
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 3685-84-5
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009520
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C12H17Cl2NO3
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C12H16ClNO3.ClH/c1-14(2)7-8-16-12(15)9-17-11-5-3-10(13)4-6-11;/h3-6H,7-9H2,1-2H3;1H
InChIKey FIVHOHCAXWQPGC-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 246
Optical Filter Setting Open
Peak Amplitude 1711
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU M2460-1G
SMILES Cl.c1cc(ccc1OCC(OCCN(C)C)=O)Cl
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 2-(4-Chlorophenoxy)acetic acid 2-(dimethylamino)ethyl ester hydrochloride
Technique FT-Raman
Zero Filling Factor 4