For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Ethyl 1-tert-butyloxycarbonyl-DL-nipecotate
SpectraBase Compound ID DbCa7qFWGZi
InChI InChI=1S/C13H23NO4/c1-5-17-11(15)10-7-6-8-14(9-10)12(16)18-13(2,3)4/h10H,5-9H2,1-4H3
InChIKey YCXCRFGBFZTUSU-UHFFFAOYSA-N
Mol Weight 257.33 g/mol
Molecular Formula C13H23NO4
Exact Mass 257.162708 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 4QbLM9lcnNp
Name Ethyl 1-tert-butyloxycarbonyl-DL-nipecotate
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H32704
Lot Number 10154955
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270476
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1852
Backward Peak Location 7340
Beam Splitter Setting KBr
CAS Registry Number 130250-54-3
Color Properties White
Container ID C-009760
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C13H23NO4
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C13H23NO4/c1-5-17-11(15)10-7-6-8-14(9-10)12(16)18-13(2,3)4/h10H,5-9H2,1-4H3
InChIKey YCXCRFGBFZTUSU-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 257.330 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1880
Peak Amplitude 2nd Channel 1
Peak Location 7396
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 0 %
Resolution 4
SKU H32704-1G
SMILES C1C(CN(CC1)C(OC(C)(C)C)=O)C(OCC)=O
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.292 s
Scanner Temperature 28.3 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms Ethyl N-Boc-piperidine-3-carboxylate; 1-Boc-DL-Nipecotic acid ethyl ester
Technique ATR-Neat
Zero Filling Factor 4