For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Bis(pentafluorophenyl) carbonate
SpectraBase Compound ID G2VjnU3NB5o
InChI InChI=1S/C13F10O3/c14-1-3(16)7(20)11(8(21)4(1)17)25-13(24)26-12-9(22)5(18)2(15)6(19)10(12)23
InChIKey IOVVFSGCNWQFQT-UHFFFAOYSA-N
Mol Weight 394.12 g/mol
Molecular Formula C13F10O3
Exact Mass 393.968775 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 4KdGhNI1pfa
Name Bis(pentafluorophenyl) carbonate
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H54880
Lot Number BC160501
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270562
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -8878
Backward Peak Location 14491
Beam Splitter Setting KBr
CAS Registry Number 59483-84-0
Container ID C-009779
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C13F10O3
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C13F10O3/c14-1-3(16)7(20)11(8(21)4(1)17)25-13(24)26-12-9(22)5(18)2(15)6(19)10(12)23
InChIKey IOVVFSGCNWQFQT-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 394.124 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -8974
Peak Amplitude 2nd Channel 1
Peak Location 14465
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 98+%
Relative Humidity Interferometer 0 %
Resolution 2
SKU H54880-1G
SMILES c1(c(c(c(c(c1F)F)F)F)F)OC(Oc1c(c(c(c(c1F)F)F)F)F)=O
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.041 s
Scanner Temperature 29.6 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Solvent Dichloromethane
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms Pentafluorophenyl carbonate
Technique Film
Window KBr Window
Zero Filling Factor 8