SpectraBase Spectrum ID |
4DUAyq2J9kc |
Name |
Chlorotri(1-pyrrolidinyl)phosphonium hexafluorophosphate |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H54693 |
Lot Number |
BD010504 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
1 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.222573 |
Analog Signal 2 |
0 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Backward Peak Amplitude |
2075 |
Backward Peak Location |
28701 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
133894-48-1 |
Calibration Lamp Spectrum |
Correction.0 |
Color Properties |
Pale brown |
Container ID |
C-009953 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C12H24ClF6N3P2 |
Frequency of First Point |
3597.77 cm⁻¹ |
Frequency of Last Point |
-0.855506 cm⁻¹ |
High Folding Limit |
31596.9 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C12H24ClN3P.F6P/c13-17(14-7-1-2-8-14,15-9-3-4-10-15)16-11-5-6-12-16;1-7(2,3,4,5)6/h1-12H2;/q+1;-1 |
InChIKey |
BSCYRXJVGSZNKX-UHFFFAOYSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Molecular Weight |
421.736 g/mol |
Non Linearity Correction |
0 |
Number of Points |
7465 |
Number of Sample Scans |
128 |
Optical Filter Setting |
Open |
Peak Amplitude |
2024 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
28683 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Solid |
Preamplifier Gain |
0 |
Purity |
98+% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Relative Humidity Interferometer |
30 % |
Resolution |
2 |
SKU |
H54693-1G |
SMILES |
C1N(CCC1)[P+](N1CCCC1)(Cl)N1CCCC1.F[P-](F)(F)(F)(F)F |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
794.714 s |
Scanner Temperature |
25.8 °C |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Technique |
FT-Raman |
Temperature of Calibration Lamp |
2300 |
Zero Filling Factor |
4 |