SpectraBase Spectrum ID |
41QPYvjcTTB |
Name |
N-(9-Fluorenylmethyloxycarbonyl)-O-tert-butyl-D-tyrosine |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H62765 |
Lot Number |
5015R18Q |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Additional Data Treatment |
1 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Backward Peak Amplitude |
2947 |
Backward Peak Location |
28687 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
118488-18-9 |
Calibration Lamp Spectrum |
Correction.0 |
Container ID |
C-009762 |
Copyright |
Copyright © 2017-2025 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C28H29NO5 |
Frequency of First Point |
3597.79 cm⁻¹ |
Frequency of Last Point |
-1.31092 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C28H29NO5/c1-28(2,3)34-19-14-12-18(13-15-19)16-25(26(30)31)29-27(32)33-17-24-22-10-6-4-8-20(22)21-9-5-7-11-23(21)24/h4-15,24-25H,16-17H2,1-3H3,(H,29,32)(H,30,31)/t25-/m1/s1 |
InChIKey |
JAUKCFULLJFBFN-RUZDIDTESA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Molecular Weight |
459.542 g/mol |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
230 |
Optical Filter Setting |
Open |
Peak Amplitude |
-2873 |
Peak Location |
28693 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Liquid |
Preamplifier Gain |
0 |
Purity |
95% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Resolution |
2 |
SKU |
H62765-1G |
SMILES |
OC([C@@](Cc1ccc(cc1)OC(C)(C)C)(NC(OCC1c2ccccc2-c2ccccc12)=O)[H])=O |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
0 s |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
(R)-2-((((9H-Fluoren-9-yl)methoxy)carbonyl)amino)-3-(4-(tert-butoxy)phenyl)propanoic acid |
Technique |
FT-Raman |
Zero Filling Factor |
4 |