ABQKHKWXTUVKGF-UHFFFAOYSA-N
SpectraBase Compound ID GX6qlFOAttf
InChI InChI=1S/C8H7NS/c1-7-2-4-8(5-3-7)9-6-10/h2-5H,1H3
InChIKey ABQKHKWXTUVKGF-UHFFFAOYSA-N
Mol Weight 149.21 g/mol
Molecular Formula C8H7NS
Exact Mass 149.02992 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 3qxT3VaD5Cm
Name p-Tolyl isothiocyanate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number I0393
Lot Number G6LXA-SD
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.27056
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1708
Backward Peak Location 7348
Beam Splitter Setting KBr
CAS Registry Number 622-59-3
Color Properties Light yellow
Container ID C-010162
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C8H7NS
Frequency of First Point 3998.29 cm⁻¹
Frequency of Last Point 339.459 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C8H7NS/c1-7-2-4-8(5-3-7)9-6-10/h2-5H,1H3
InChIKey ABQKHKWXTUVKGF-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 149.211 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1747
Peak Amplitude 2nd Channel 1
Peak Location 7387
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 20 %
Resolution 4
SKU I0393-5G
SMILES c1cc(ccc1N=C=S)C
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.333 s
Scanner Temperature 28.2 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms Isothiocyanic acid p-tolyl ester; 4-Methylphenyl isothiocyanate
Technique ATR-Neat
Zero Filling Factor 4