3'-Chloro-4'-hydroxyacetophenone
SpectraBase Compound ID 3j4GU76ek5O
InChI InChI=1S/C8H7ClO2/c1-5(10)6-2-3-8(11)7(9)4-6/h2-4,11H,1H3
InChIKey GMTSPBYBJKGPJF-UHFFFAOYSA-N
Mol Weight 170.59 g/mol
Molecular Formula C8H7ClO2
Exact Mass 170.013457 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 3hwPCp3GnNt
Name 3'-Chloro-4'-hydroxyacetophenone
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number C3076
Lot Number 8D4XN-TJ
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2210
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 2892-29-7
Calibration Lamp Spectrum Correction.0
Color Properties Pale reddish yellow
Container ID C-009638
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H7ClO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H7ClO2/c1-5(10)6-2-3-8(11)7(9)4-6/h2-4,11H,1H3
InChIKey GMTSPBYBJKGPJF-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 206
Optical Filter Setting Open
Peak Amplitude 2185
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU C3076-1G
SMILES Oc1c(cc(cc1)C(C)=O)Cl
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 1-(3-Chloro-4-hydroxyphenyl)ethanone
Technique FT-Raman
Zero Filling Factor 4