SpectraBase Spectrum ID |
3OjqMft8dAR |
Name |
Disopyramide |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
D2793 |
Lot Number |
WUZ2O-DP |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.27023 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-10539 |
Backward Peak Location |
14479 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
3737-09-5 |
Color Properties |
White |
Container ID |
C-009586 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C21H29N3O |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C21H29N3O/c1-16(2)24(17(3)4)15-13-21(20(22)25,18-10-6-5-7-11-18)19-12-8-9-14-23-19/h5-12,14,16-17H,13,15H2,1-4H3,(H2,22,25) |
InChIKey |
UVTNFZQICZKOEM-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
339.483 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-9944 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14477 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Solid |
Preamplifier Gain Background |
0 |
Purity |
96% |
Relative Humidity Interferometer |
20 % |
Resolution |
2 |
SKU |
D2793-1G |
SMILES |
NC(C(c1ccccn1)(CCN(C(C)C)C(C)C)c1ccccc1)=O |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.053 s |
Scanner Temperature |
26.6 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
α-Diisopropylaminoethyl-α-phenylpyridine-2-acetamide; 4-(Diisopropylamino)-2-phenyl-2-(2-pyridyl)butyramide |
Technique |
KBr0 |
Zero Filling Factor |
8 |