Ethyl trans-3-(3-pyridyl)acrylate
SpectraBase Compound ID HVBPE3SYIjE
InChI InChI=1S/C10H11NO2/c1-2-13-10(12)6-5-9-4-3-7-11-8-9/h3-8H,2H2,1H3/b6-5+
InChIKey PIEQSBWGIODYPE-AATRIKPKSA-N
Mol Weight 177.2 g/mol
Molecular Formula C10H11NO2
Exact Mass 177.078979 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 3MGnHOI2dQl
Name Ethyl trans-3-(3-pyridyl)acrylate
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H33964
Lot Number 10169551
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 4746
Backward Peak Location 28687
Beam Splitter Setting Quartz
Calibration Lamp Spectrum Correction.0
Color Properties Pale yellow
Container ID C-009819
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C10H11NO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C10H11NO2/c1-2-13-10(12)6-5-9-4-3-7-11-8-9/h3-8H,2H2,1H3/b6-5+
InChIKey PIEQSBWGIODYPE-AATRIKPKSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 177.203 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 434
Optical Filter Setting Open
Peak Amplitude -4466
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 96%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H33964-1G
SMILES c1c(cncc1)\C=C\C(OCC)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms trans-3-(3-Pyridyl)acrylic acid ethyl ester
Technique FT-Raman
Zero Filling Factor 4