4-Bromo-dibenzothiophene
SpectraBase Compound ID 3c3Kerbd7yZ
InChI InChI=1S/C12H7BrS/c13-10-6-3-5-9-8-4-1-2-7-11(8)14-12(9)10/h1-7H
InChIKey GJXAVNQWIVUQOD-UHFFFAOYSA-N
Mol Weight 263.15 g/mol
Molecular Formula C12H7BrS
Exact Mass 261.945184 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 3CCuBBjPaOR
Name 4-Bromodibenzothiophene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B4449
Lot Number I8FWH-EH
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 7518
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 73323-65-6
Calibration Lamp Spectrum Correction.0
Color Properties White-pale yellow
Container ID C-009450
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C12H7BrS
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C12H7BrS/c13-10-6-3-5-9-8-4-1-2-7-11(8)14-12(9)10/h1-7H
InChIKey GJXAVNQWIVUQOD-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 263.152 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 256
Optical Filter Setting Open
Peak Amplitude 7476
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B4449-1G
SMILES c12sc3c(cccc3c1cccc2)Br
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4