5-Fluoro-2-(trifluoromethyl)phenylacetic acid
SpectraBase Compound ID 6IbSFo7y6m9
InChI InChI=1S/C9H6F4O2/c10-6-1-2-7(9(11,12)13)5(3-6)4-8(14)15/h1-3H,4H2,(H,14,15)
InChIKey GWWZRGDMAFXULO-UHFFFAOYSA-N
Mol Weight 222.14 g/mol
Molecular Formula C9H6F4O2
Exact Mass 222.030392 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 2qf9IT9zrN0
Name 5-Fluoro-2-(trifluoromethyl)phenylacetic acid
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H26696
Lot Number 10137784
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270429
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1780
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 239135-52-5
Color Properties White
Container ID C-009910
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C9H6F4O2
Frequency of First Point 3998.29 cm⁻¹
Frequency of Last Point 339.46 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C9H6F4O2/c10-6-1-2-7(9(11,12)13)5(3-6)4-8(14)15/h1-3H,4H2,(H,14,15)
InChIKey GWWZRGDMAFXULO-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 222.139 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1850
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 20 %
Resolution 4
SKU H26696-1G
SMILES C(F)(F)(F)c1c(CC(O)=O)cc(cc1)F
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.292 s
Scanner Temperature 28.3 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4