2,4,5-Trifluorobenzenesulfonyl chloride
SpectraBase Compound ID EvOOd5LwCbL
InChI InChI=1S/C6H2ClF3O2S/c7-13(11,12)6-2-4(9)3(8)1-5(6)10/h1-2H
InChIKey STCZWXXRRTWRSK-UHFFFAOYSA-N
Mol Weight 230.59 g/mol
Molecular Formula C6H2ClF3O2S
Exact Mass 229.941613 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 2kVCYdOWhwG
Name 2,4,5-Trifluorobenzenesulfonyl chloride
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number T3128
Lot Number 73MAD-GT
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270343
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1893
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 220227-21-4
Color Properties Colorless-pale yellow
Container ID C-009436
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C6H2ClF3O2S
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C6H2ClF3O2S/c7-13(11,12)6-2-4(9)3(8)1-5(6)10/h1-2H
InChIKey STCZWXXRRTWRSK-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 230.588 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1850
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 4
SKU T3128-1G
SMILES c1c(c(cc(c1F)F)F)S(=O)(=O)Cl
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.308 s
Scanner Temperature 27.4 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4