2-Bromo-4-iodopyridine
SpectraBase Compound ID 6qcQg4AmNAZ
InChI InChI=1S/C5H3BrIN/c6-5-3-4(7)1-2-8-5/h1-3H
InChIKey HPKRNLGLZYOVJS-UHFFFAOYSA-N
Mol Weight 283.89 g/mol
Molecular Formula C5H3BrIN
Exact Mass 282.849357 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 2Z4ZsE9lphD
Name 2-Bromo-4-iodopyridine
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B5119
Lot Number NDHSO-FS
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1987
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 100523-96-4
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009614
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C5H3BrIN
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C5H3BrIN/c6-5-3-4(7)1-2-8-5/h1-3H
InChIKey HPKRNLGLZYOVJS-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 283.894 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 6
Optical Filter Setting Open
Peak Amplitude 1934
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B5119-1G
SMILES c1c(nccc1I)Br
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4