2-Chloro-6-nitro-4-(trifluoromethyl)aniline
SpectraBase Compound ID KLGuG7SW49W
InChI InChI=1S/C7H4ClF3N2O2/c8-4-1-3(7(9,10)11)2-5(6(4)12)13(14)15/h1-2H,12H2
InChIKey JLWRJMVXRUKFPA-UHFFFAOYSA-N
Mol Weight 240.57 g/mol
Molecular Formula C7H4ClF3N2O2
Exact Mass 239.99134 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 2VbGO5ElwoS
Name 2-Chloro-6-nitro-4-(trifluoromethyl)aniline
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number B20938
Lot Number 10143712
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 3592
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 57729-79-0
Calibration Lamp Spectrum Correction.0
Color Properties Yellow
Container ID C-009893
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C7H4ClF3N2O2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C7H4ClF3N2O2/c8-4-1-3(7(9,10)11)2-5(6(4)12)13(14)15/h1-2H,12H2
InChIKey JLWRJMVXRUKFPA-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 240.569 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 220
Optical Filter Setting Open
Peak Amplitude -3480
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B20938-1G
SMILES C(F)(F)(F)c1cc(c(c(c1)N(=O)=O)N)Cl
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 4-Amino-3-chloro-5-nitrobenzotrifluoride
Technique FT-Raman
Zero Filling Factor 4