Pyrazole-3-carboxylic acid
SpectraBase Compound ID KxQ29UV0cn1
InChI InChI=1S/C4H4N2O2/c7-4(8)3-1-2-5-6-3/h1-2H,(H,5,6)(H,7,8)
InChIKey KOPFEFZSAMLEHK-UHFFFAOYSA-N
Mol Weight 112.09 g/mol
Molecular Formula C4H4N2O2
Exact Mass 112.027277 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 2HmpL2FKTin
Name Pyrazole-3-carboxylic acid
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number P1862
Lot Number 35UND-CK
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2360
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 1621-91-6
Calibration Lamp Spectrum Correction.0
Color Properties White-pale yellow
Container ID C-009502
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C4H4N2O2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C4H4N2O2/c7-4(8)3-1-2-5-6-3/h1-2H,(H,5,6)(H,7,8)
InChIKey KOPFEFZSAMLEHK-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 112.088 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 122
Optical Filter Setting Open
Peak Amplitude 2362
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU P1862-1G
SMILES [nH]1nc(C(O)=O)cc1
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 5-Pyrazolecarboxylic acid
Technique FT-Raman
Zero Filling Factor 4