SpectraBase Spectrum ID |
2H2C4Ug4ej1 |
Name |
3-Allylrhodanine |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
A1412 |
Lot Number |
2SC7D-E0 |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
16 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270555 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1377 |
Backward Peak Location |
7370 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
1457-47-2 |
Color Properties |
Yellow |
Container ID |
C-010398 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C6H7NOS2 |
Frequency of First Point |
3998.31 cm⁻¹ |
Frequency of Last Point |
339.461 cm⁻¹ |
High Folding Limit |
15800.4 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C6H7NOS2/c1-2-3-7-5(8)4-10-6(7)9/h2H,1,3-4H2 |
InChIKey |
GYGUTBCTEJBRAN-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1334 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7366 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Solid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
>98.0% |
Relative Humidity Interferometer |
20 % |
Resolution |
4 |
SKU |
A1412-5G |
SMILES |
C1SC(N(C1=O)CC=C)=S |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.301 s |
Scanner Temperature |
29 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
3-Allyl-2-thioxo-4-thiazolidinone; 3-(Prop-2-en-1-yl)-2-thioxo-1,3-thiazolidin-4-one |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |