(8-Quinolinolato)lithium
SpectraBase Compound ID JLkiplY6HPy
InChI InChI=1S/C9H7NO.Li/c11-8-5-1-3-7-4-2-6-10-9(7)8;/h1-6,11H;/q;+1/p-1
InChIKey FQHFBFXXYOQXMN-UHFFFAOYSA-M
Mol Weight 151.09 g/mol
Molecular Formula C9H6LiNO
Exact Mass 151.060942 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 1xLDUvjCaRs
Name (8-Quinolinolato)lithium
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number Q0100
Lot Number CTWFB-OQ
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2645
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 25387-93-3
Calibration Lamp Spectrum Correction.0
Color Properties Pale yellow
Container ID C-009736
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C9H6LiNO
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C9H7NO.Li/c11-8-5-1-3-7-4-2-6-10-9(7)8;/h1-6,11H;/q;+1/p-1
InChIKey FQHFBFXXYOQXMN-UHFFFAOYSA-M
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 151.093 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 256
Optical Filter Setting Open
Peak Amplitude 2644
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU Q0100-1G
SMILES [Li+].c12cccc(c1nccc2)[O-]
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4