For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
SpectraBase Compound ID AuG20Db3qgF

Vapor Phase (Gas) Infrared Spectrum

Vapor Phase (Gas) Infrared Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 1QQAUJNzS9M
Name E-264 H - Controlled Pyrolyzate (Vapor Phase)
Source of Sample Fiberite Corporation
Chemical Description EPOXY MOLDING COMPOUND
Copyright Copyright © 1980, 1981-2024 John Wiley & Sons, Inc. All Rights Reserved.
Deflection Temperature (264 PSI) 250C
Density (Specific Gravity)= 1.86-1.92
Hardness (ROCKWELL M SCALE) 105
Sample Procedure The pyrolysis technique is commonly used in the infrared identification of polymers and results in spectra of both the volatile and non-volatile pyrolyzed fractions the polymer under investigation. It can be used by researchers to identify principal polymer types. This record contains the volatile (Vapor Phase) IR spectrum resulting from the pyrolysis of E-264 H. The IR spectrum of the non-volatile (Condensed Phase) fraction resulting from the pyrolysis of E-264 H is E-264 H - Controlled Pyrolyzate (Condensed Phase). The Temperature in this record is the temperature of the pyrolysis.
Technique Vapor Phase
Water Absorption (50C, 48 HRS) 0.15%