SpectraBase Spectrum ID |
1G6Uiw2OFXM |
Name |
trans,trans-4'-(3-Butenyl)-4-(p-tolyl)bicyclohexyl |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
B4915 |
Lot Number |
II4LI-CG |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
8 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270384 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1903 |
Backward Peak Location |
7372 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
129738-42-7 |
Color Properties |
White |
Container ID |
C-009619 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C23H34 |
Frequency of First Point |
3998.34 cm⁻¹ |
Frequency of Last Point |
339.463 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C23H34/c1-3-4-5-19-8-12-21(13-9-19)23-16-14-22(15-17-23)20-10-6-18(2)7-11-20/h3,6-7,10-11,19,21-23H,1,4-5,8-9,12-17H2,2H3/t19-,21?,22-,23? |
InChIKey |
OXPUOKDPOMJNKA-CBTVVQEUSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-2015 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7364 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Solid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
98% |
Relative Humidity Interferometer |
10 % |
Resolution |
4 |
SKU |
B4915-1G |
SMILES |
c1c(ccc(c1)[C@]1(CCC(CC1)C1CC[C@@](CC1)(CCC=C)[H])[H])C |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.309 s |
Scanner Temperature |
28.2 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
1-[4-(4-But-3-enylcyclohexyl)cyclohexyl]-4-methylbenzene |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |