For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
[trans-4-(4-Chlorophenyl)cyclohexyl]methanol
SpectraBase Compound ID 9PKAuzIBXWY
InChI InChI=1S/C13H17ClO/c14-13-7-5-12(6-8-13)11-3-1-10(9-15)2-4-11/h5-8,10-11,15H,1-4,9H2/t10-,11-
InChIKey INSWJXJRICZMOG-XYPYZODXSA-N
Mol Weight 224.73 g/mol
Molecular Formula C13H17ClO
Exact Mass 224.096793 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID Da8GRQwWnoI
Name [trans-4-(4-Chlorophenyl)cyclohexyl]methanol
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H33308
Lot Number 10164041
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 4004
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 137736-28-8
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009854
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C13H17ClO
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C13H17ClO/c14-13-7-5-12(6-8-13)11-3-1-10(9-15)2-4-11/h5-8,10-11,15H,1-4,9H2/t10-,11-
InChIKey INSWJXJRICZMOG-XYPYZODXSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 150
Optical Filter Setting Open
Peak Amplitude -3854
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H33308-1G
SMILES OC[C@@]1(CC[C@](CC1)(c1ccc(cc1)Cl)[H])[H]
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4